Files
dashboards/README.md
T
ducoterra de325caa49 phase: 06_system_page_gpu_verdicts
All criteria verified and the project is fully green.

**Verified (final pass — all 3 phase-06 tasks were already in `complete/`)**
- `classify("gpu.busy_pct", 99)` / `gpu.mem_used_pct` → `None`; `THRESHOLDS` has no `gpu.*` row; `alerts.py`/`api.py` carry no GPU verdict; live browser: deskwork GPU at **91 %** and **98 %** renders `class="hero"`, `color=rgb(22,25,31)` (plain text), no bar, no `.sev-*`.
- GPU temp on the hero `.sub` from live agents: `Radeon 8060S Graphics · VRAM 165.1 MiB / 512.0 MiB · pool 78% · 48 °C`, R9700 `· 40 °C`, gateway prints none (no `n/a`, no `0 °C`).
- Charts collapsed by default: fresh load = 3 panels / 3 toggles / **0 open / 0 `<svg>`**; expand → 3 SVGs (510 px wide), repaints across polls (legend 3.3 %→5.6 %), collapsed siblings keep their own height (803 vs 358/339).
- `gpu.busy_pct@0` still answers from `/api/system/history` (345 points) — verdict gone, data intact.

**Tests / lint / coverage**
- `bash .agents/validate.sh` → **EXIT=0**; `uv run pytest --cov --cov-fail-under=94` → **550 passed, 8 skipped, 97.91 %**; `uv run ruff check src tests agent` → clean; `uv run pyright` → 0 errors; `node --check` all scripts clean; `uv pip list --outdated` empty.
- `uv run pytest -m live --live` → **8 passed** (real agents/engines/upsd); dev server restarted, `/api/health` all sources `ok`.
- New screenshots: `data/logs/phase06-final-collapsed-default.png`, `data/logs/phase06-final-expanded-gpu-busy-uncoloured.png`.

**Completion criteria:** classify→None ✅ · pytest+94 % gate ✅ · ruff+pyright ✅ · validate.sh ✅ · screenshots of the three behaviours on live data ✅ · AGENTS.md severity section claims no GPU rows ✅

**Docs:** fixed 3 items — (1) `AGENTS.md` pytest count stale (546 → 550); (2) `app.js` `severityFor` docstring still claimed "`page-ups.js` still calls it (phase 05 converts it)", contradicting the code/tests/AGENTS.md (comment-only); rest of README/AGENTS reviewed in full (env table vs `config.py`+`.env.example`, agent routes incl. `/schema`, alerts rules, page descriptions, contracts) — consistent.

**Notable:** fixed a real pre-existing defect in `scripts/dev-server.sh` — `stop` slept 1 s and deleted the pidfile without waiting for exit, so `restart` with a browser open overlapped two servers on one SQLite file, producing a `database is locked` store refusal that `/system` rendered as a red event. Now waits (bounded 20 s) then SIGKILLs; verified a restart with live polling logs no such error/event. No live infra config was changed.

**Next pending phase:** `.agents/phases/todo/07_llm_monitor_style_pages`
2026-10-17 14:04:52 -04:00

307 lines
21 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Homelab Dashboards
Three dashboards, one domain, one process, one SQLite file:
| Page | What it answers | Source |
| ----------- | ------------------------------------------------------------------------------- | -------------------------------------------------- |
| `/` | Is anything wrong, and which dashboard do I need? | fleet + alerts in one request (`/api/summary`) |
| `/system` | What are my machines doing — CPU, memory, disk, GPU, network, and the history of all of it | `agent/host_agent.py`, our own stdlib agent per host |
| `/llm` | Tokens/sec, active sessions, queue depth, KV-cache pressure, latency percentiles | llama.cpp-family (gufo) + vLLM `/metrics`, read-only |
| `/ups` | Battery health, runtime left, power events, and battery-test buttons | NUT `upsd`, on whatever port it really listens on (its own wire-protocol client) |
No Prometheus, no Grafana, no CDN, no build step. Nothing is fetched from the internet at
runtime; every asset is served by this app.
Working on this repo? **[`AGENTS.md`](AGENTS.md)** holds the invariants (read-only by
construction, never invent a number, unconfigured ≠ broken), the locked decisions, the real
fleet facts, and the known gaps.
## Quickstart
```bash
uv sync --python 3.14 # deps + the package, editable
cp .env.example .env # then edit
uv run dashboards # http://127.0.0.1:8090
uv run uvicorn dashboards.app:app --port 8090 # equivalent
uv run pytest # unit tests, no network needed
```
Developing against the real fleet from a laptop (agents stay unexposed — ssh forwards
them to localhost):
```bash
cp .env.dev.example .env.dev # your ssh aliases + which ports
python3 - <<'PY' # push the agent to each host (once)
import shlex, subprocess, pathlib
for host in ("driveripper-ops", "deskwork-ops", "gateway-ops"):
subprocess.run(["ssh", host, "mkdir -p ~/lab-agent"], check=True)
subprocess.run(["scp", "agent/host_agent.py", f"{host}:~/lab-agent/"], check=True)
PY
./scripts/dev-tunnels.sh start # 9121/9122/9123 -> each host's agent,
# + DEV_FORWARDS -> upsd on 127.0.0.1:3494
# (the remote port is upsd's real one — 3051
# on driveripper, not the 3493 default)
set -a; . ./.env.dev; set +a
uv run dashboards # foreground
./scripts/dev-server.sh restart # or backgrounded, with a pidfile + logs
```
`DEV_TUNNELS` starts the agent remotely and forwards it; `DEV_FORWARDS` forwards a service
that already listens there (upsd) — that is how the UPS page reads a real battery without
3493 being reachable from anywhere but this laptop.
## The host agent
`agent/host_agent.py` is one file, **stdlib only**, Python 3.10+. It reads `/proc`,
`/sys/block`, `/sys/class/drm` and `statvfs` and answers `GET /snapshot` (everything, one
JSON document; `?top=N` trims the process lists), `GET /info` (slow-changing identity: OS,
kernel, CPU model, GPU list), `GET /schema` (the schema version plus this document) and
`GET /health` (the one route that never needs the token) as JSON, with a plain HTML status
page at `GET /` so a browser pointed at an agent learns what it is looking at.
```bash
python3 host_agent.py --once # print one snapshot, exit
python3 host_agent.py --host 0.0.0.0 --port 9120 --token-file /etc/dashboards-agent.token
sudo deploy/install-agent.sh # systemd unit + user + token
deploy/install-agent.sh --status # unit state and /health
sudo deploy/install-agent.sh --uninstall
```
It is read-only by construction: there is no code path that writes, and the HTTP server
only answers `GET`. Counters are reported as counters — the dashboard computes rates over
a labelled window, so the agent never has to remember who polled it last.
Binding off-loopback without a token is refused (exit 2) rather than warned about. Prefer
`--token-file` over `--token`: argv is world-readable through `ps`, and this token guards
hostname, mounts, disk and GPU models, and process names. `deploy/install-agent.sh` creates
a system user, generates a token once (re-runs reuse it; `--rotate-token` for a new one),
stores it `0600` root-owned, and runs the agent under `ProtectSystem=strict` with no
capabilities — enough to read `/proc`, `/sys` and `statvfs()` and nothing else.
## Configuration
Everything comes from the environment (see `.env.example` for the annotated list). At
startup a `.env` next to the checkout is loaded first if it exists — as a *seed*: a
variable the container, systemd unit, or your shell already set always wins. Point
`DASH_ENV_FILE` somewhere else to keep several installs on one box. `.env.example` is
documentation and is never loaded, and `scripts/dev-server.sh` exports `.env.dev` itself
(see the quickstart) because dev settings must not leak into a production process.
| Variable | Meaning |
| ------------------------------------- | -------------------------------------------------------------- |
| `HOST_TARGETS` | `name=url` per host running the agent; a bearer token may ride in the URL userinfo (`http://TOKEN@host:9120`) |
| `GUFO_BASE_URL` / `VLLM_BASE_URL` | LLM engines; unset means *not deployed here*, and its half of the page disappears |
| `RATE_WINDOW_SECONDS` | the Δ window behind every measured rate — tokens/sec, bytes/sec, jiffies→CPU % (default 10); each value carries the window it actually got, and `/system`'s footnote prints that, not this default |
| `DASH_HOST` / `DASH_PORT` | bind address for the dashboard itself (default `127.0.0.1:8090`; the container sets `0.0.0.0`) |
| `HOST_INTERVAL_SECONDS` / `LLM_INTERVAL_SECONDS` / `NUT_INTERVAL_SECONDS` | how often each source is polled (10 / 2 / 5 s) |
| `HOST_TIMEOUT_SECONDS` / `LLM_TIMEOUT_SECONDS` / `NUT_TIMEOUT_SECONDS` | per-source fetch timeout — one slow source never holds up the others |
| `GUFO_API_KEY` / `VLLM_API_KEY` | only if an engine is behind a bearer token; they never leave the server |
| `NUT_HOST` / `NUT_PORT` | upsd address — **whatever port it really listens on**, not always 3493. Reads are unauthenticated in stock NUT |
| `NUT_USER` / `NUT_PASSWORD` | only needed for instant commands (battery tests) |
| `NUT_ALLOW_ACTIONS` | `1` enables the one write endpoint in the app |
| `NUT_SIMULATE` | `1` replaces upsd with a **labelled** simulator (development only) |
| `DASH_READ_ONLY` | `1` disables every mutating endpoint regardless of other flags |
| `DASH_DB` | SQLite path (default `data/dashboards.sqlite3`) |
| `POLL_MS_SYSTEM` / `POLL_MS_LLM` / `POLL_MS_UPS` | how often the *browser* refetches each page (10 s / 2 s / 5 s) — shown in the page footer |
| `DEBUGPY` / `DEBUGPY_PORT` | `DEBUGPY=1` opens a debugpy listener (default 5678) without blocking startup |
| `RETAIN_RAW_HOURS` / `RETAIN_MINUTE_DAYS` / `RETAIN_HOUR_DAYS` | history rollup and pruning |
A source that is not configured answers `404 {"configured": false}` **without dialling**,
and the page says "not configured" instead of showing a red panel for something you never
installed.
Nothing that leaves the app carries a credential. A `HOST_TARGETS` userinfo token is parsed
into an `Authorization` header, and every URL the browser can see — `/api/config`, a source's
error string, the event feed — goes through `config.strip_userinfo` first, because an
unreachable host writes its failure message into the event table and `/api/events` serves it.
## Architecture
```
agent/host_agent.py (each host) gufo / vLLM upsd (NUT)
│ GET /snapshot │ GET /metrics │ LIST UPS / LIST VAR / LIST CMD
▼ ▼ ▼
src/dashboards/collectors.py ────────────────────────────────────────────┐
│ parse + Δcounter/Δt (rates.py) │
▼ ▼
sources/host.py · sources/llm.py · sources/nut.py poller.py (one task per source)
│ samples events │
▼ ▼
store.py ── SQLite (WAL): sample(source,host,metric,res,ts) + event ── api.py → web/
```
* `poller.py` — every source gets its own asyncio task, its own health record, and its own
error handling. A dead host keeps its last good values and is labelled stale; it never
blanks or blocks another source. And it never quietly *stops*: the task is that source's only
poller, so a SQLite write that gets refused is reported (`ok: false`, the real reason, the
numbers aging, one line in the event log) instead of freezing the source under a green dot.
* `store.py` — raw samples roll up to 1-minute and 1-hour averages and the raw rows are
pruned, so a year of history is a few hundred MB rather than a disk emergency.
* `severity.py` — the single green/amber/red table (`THRESHOLDS`, plus `INVERTED` for the
metrics where lower is worse). Rated values in the API payloads travel with a sibling
`severity` (`cpu.severity.usage_pct`, `memory.severity`, `disks.severity`, a UPS card's
`severity.charge_pct`, `severity` inside the rated LLM
cells such as KV pressure, `/api/summary` rows), computed server-side, so every page
colours the same way and a value nobody reported renders `n/a` instead of green. A metric
published as a 0-1 ratio is rescaled *for the verdict only* — the number printed stays
what the upstream published. There is no `gpu.*` row: these are LLM servers, a busy GPU
is the job, so the GPU card (and the fleet GPU column) renders uncoloured at every
utilisation — the `gpu.*` history series are still stored and charted.
* `alerts.py` — "what is wrong right now", as data. `alerts.build(settings, job_states,
host_payloads, engine_payloads, ups_payload, recent_events)` is a pure projection of the
state the poller already keeps plus the verdicts `severity.py` and the UPS health checks
already reached — no I/O, no thresholds of its own — and `/api/summary` returns it as
`alerts`, worst first: `{id, severity, source, message, href, at}`. A configured source
that stopped answering is `fail`; one that is stale but still serving its last good value
is `warn`; an **unconfigured** source never alerts; a dead source is one line rather than
one per stale metric; the list dedupes per (source, metric) and is capped at 12 with a
marker that says how many it hid.
* `web/` — four static pages, one stylesheet, hand-rolled SVG charts (`charts.js`). No
framework, no CDN, no bundler. The overview (`/`) is exactly two panels — a
**Warnings & errors** list built from `/api/summary`'s `alerts` (each row links to the
dashboard that explains it) and the **Fleet** table — and nothing else: an empty alert
list reads as an explicit "all clear", and a live problem moves the panel above the
table. A host that is not answering keeps its row — dimmed, every number `n/a` — so the
fleet never quietly gets smaller and last good values are never mistaken for live ones.
A big colour-coded number is `Dash.hero(el, {...})` on the
`.hero` / `.hero-bar` styles, coloured by the `severity` in the payload via
`Dash.severityFrom()` — the only colour vocabulary is `ok` / `warn` / `fail`, and a value
with no verdict renders `n/a` with no colour at all. A battery is
`DashCharts.battery(el, {charge, severity, state, label})`: one inline SVG whose fill *is* the
charge — clamped to 0–100, never rounded up, clipped to the plate so 0 % is an empty shell —
coloured only by the payload verdict, with a shape per state (solid shell on line, bolt
charging, dashed outline on battery, a dash through the body when there is no reading) and a
`<title>` / `aria-label` that names it ("apc: Charge 100 percent, on line") unless the number
beside it already does. Each `/system` host is one panel led
by exactly six of them — CPU %, MEM %, TEMP, DISK % (mount underneath), GPU busy (VRAM, the
APU pool and the card's temperature in the footnote — no temperature is printed when the
driver exposes no sensor, never `0 °C`; and likewise never coloured and with no bar: a busy
GPU is the job on an LLM server), and NET on two lines (↓ in / ↑ out, never coloured: a byte
rate has no good/bad). Under the numbers, **each panel charts only its own host** — behind a
collapsed **Charts** toggle, because the default view is current stats and a fleet of ten
hosts each drawing three plots is noise: the summary reads `▸ Charts` with the window in it
(`1h`, `24h` …), and opening it is what builds and paints the charts — instantly, from the
response the last refresh already fetched, and repainted on every refresh after that while it
stays open. Expanding one panel never stretches its collapsed siblings
(`.grid.items-start`). The stack is utilisation
(CPU, memory, worst disk), network (↓ in / ↑ out), and GPU busy for a host that reports
cards — three 120px SVG charts, each with its own legend and its own `aria-label` naming the
host and the plotted metrics (`LineChart`'s `ariaLabel` option), never a second host in sight. The
fleet-wide charts, the nine-figure fleet-totals panel and the host/metric detail picker are gone, and
so are the per-core charts, while `cpu.usage_pct@coreN` stays in SQLite. Everything else —
load, clock, disk I/O, uptime, GPU power and the per-label temp breakdown, filesystems,
processes — folds into a collapsed
"More detail" disclosure. Each panel pulls its series in **one** `/api/system/history` request
(`hosts=<that host>&metrics=…&range=…`) every refresh, stack open or not, and a host that stops
reporting takes its panel, its Charts toggle and its charts off the page. The LLM page (`/llm`) is per engine too: two big
throughput numbers (decode, prompt — uncoloured, because 0 tok/s on an idle server is
healthy) with their provenance tag (`Δ10.0s`, scraped, estimated), then a compact list of
metric rows — sessions, queue, KV pressure (the only rated cell), prefix/spec percentages,
and TTFT/TPOT/queue-time means with a `p95 …` foot line — each carrying its own sparkline
over the selected window. Preemptions and GPU-context losses render only as red alarm chips
while non-zero; the token counter is a footnote. The four trend charts sit below the panels
at half height, and one `/api/llm/history` request per refresh feeds all of it. With a
single engine configured the totals card hides and the page is one clean half — never a red
panel for a server you do not run. Each UPS card (`/ups`) opens with its battery glyph and
three big numbers — **charge %**, **load %**, **runtime left** — coloured from the card's
`severity` dict, with the electrical readings (line in, output, battery volts and amps,
battery °C) kept below them in smaller muted type because they are what you read *while* the
UPS is on battery. Health checks, the battery-test buttons (with their `DANGER`
confirmation) and the NUT variable dump are unchanged, just second.
## Testing
```bash
uv run pytest # unit + API tests, fully mocked, no network
uv run pytest --cov # coverage gate
set -a; . ./.env.dev; set +a # the live suite reads the same env as the app
uv run pytest -m live --live # optional: real fleet / engines / upsd
uv run ruff check src tests agent && uv run pyright # lint + types
./scripts/capture-fixtures.sh # re-record ground truth: host agents + UPS replies
./scripts/capture-fixtures.sh --with-llm # ... and the engines' /metrics while they are up
```
Test philosophy: **real captures as fixtures, mocks for behaviour.** Anything that must
match an upstream (`/proc` layouts, vLLM metric names, NUT protocol framing) is asserted
against a verbatim capture in `tests/fixtures/`; behaviour that needs a failure — upsd
refusing a command, an engine returning 500, a host rebooting — is a fake. The `live` tests
(`tests/test_live_fleet.py`) are the bridge: they SKIP unless you pass `--live`, each one
also skips when its source is unset (**source `.env.dev` first** — run bare and they all skip
quietly, which reads exactly like a pass), they drive the production code paths
(`collectors.*`, `NutMonitor.collect`) against whatever hardware is reachable, and they never
write — a battery test on live hardware is not a unit test.
One more file is worth knowing about: `tests/card_contract.py` is the table of
`/api/system/snapshot` paths the system page's per-host cards are allowed to read. It is
checked against all three captured host shapes (discrete GPU, APU, no GPU), over HTTP, and
again against the live fleet, so a card can never be "fixed" by inventing a number the agent
does not report. `tests/ups_contract.py` does the same job for the UPS page's hero row and
battery glyph (`charge %`, `load %`, `runtime left`, `battery_voltage`, the glyph's
`charger_status` + `on_battery`, the card header), against the two real UPSes — recorded
verbatim as `tests/fixtures/nut_<ups>.vars` by `./scripts/capture-fixtures.sh`, with the
device serials scrubbed — and again against live upsd. The captures earn their place: the
CyberPower answers `battery.mfr.date: CPS`, the APC's `battery.date` is a factory
placeholder, and **neither** publishes `battery.temperature` or `battery.charger.status`, so
a hand-written variable table would have tested nobody's memory.
## Battery-test buttons
Instant commands are the only mutating endpoint in the application (`POST /api/ups/command`)
and they are gated four times: `NUT_ALLOW_ACTIONS=1`, not `DASH_READ_ONLY`, an `upsd.users`
account that actually has the command, and a confirmation in the UI — destructive ones
(deep test, calibration, `load.off`) require typing `DANGER`. The server re-checks every
gate; hiding a button is not a safety control. Commands that would cut power are refused
outright while the UPS is already on battery.
Give the app a narrowly scoped NUT user instead of a god-mode one — per-command `instcmds`,
not `actions = -`:
```ini
# /etc/ups/upsd.users
[dashboards]
password = "..."
instcmds = test.battery.start.quick
instcmds = test.battery.start.deep
instcmds = test.battery.stop
```
One command per `instcmds` line — that is what `man 5 upsd.users` specifies ("to specify
multiple commands, use multiple instances of the instcmds field"), and a comma-separated list
on one line is not that. `instcmds = all` is the alternative, and the fleet runs that: every
command the drivers advertise, including the ones that cut output power. Nothing about the
gates changes — the risk tier, the typed `DANGER`, `NUT_ALLOW_ACTIONS` and the on-battery
refusal are what prevent a click from becoming an outage, because upsd gives the dashboard no
way to ask what an account is allowed to send.
upsd authenticates with `USERNAME` + `PASSWORD` (see `HELP` on your own server for the verbs
it accepts — `USER`/`PASS` are not among them in 2.8.5); a user needs `instcmds`, never
`actions = -`.
`deploy/nut-sudoers` is the ruleset that lets the `ops` account read (and scoped-write) those
files: `sudo install -m 0440 -o root -g root deploy/nut-sudoers /etc/sudoers.d/dashboards-nut`.
Read `upsd.users` before you write it — `upsmon` authenticates from the same file, so
overwriting it blind can take the box down at the wrong moment.
Bind upsd to loopback (`LISTEN 127.0.0.1` in `upsd.conf`) and reach it with an ssh forward
(`DEV_FORWARDS`) or a tailnet address. `NUT_SIMULATE=1` stands in for upsd during
development; everything it produces is badged `SIMULATED`, and it is never the default.
## Deployment
`Containerfile` is a two-stage build: `uv.lock` is resolved in the builder (exactly the
versions the tests ran against) and the runtime stage is slim Python with nothing but the
venv in it. The host agent is copied in too, so one image can monitor the box it runs on.
In the deployment repo the pattern is the same as every other service: quadlet container +
env template + nginx/SNI on the single domain.
```bash
podman build -t dashboards .
podman run --rm -p 8090:8090 --env-file dashboards.env \
-v dashboards-data:/var/lib/dashboards dashboards
```
It listens on `0.0.0.0:8090` as an unprivileged user, and the SQLite history lives in
`/var/lib/dashboards` — put a volume there or every restart forgets the charts. With no
sources configured `/api/health` answers `200 {"status": "empty"}`, so the container passes
its health probe before its env file is right instead of crash-looping.