Files
dashboards/AGENTS.md
T
ducoterra 1e454a8f81 Read the real UPSes: upsd lives on 3051, not 3493
Nothing was listening on 3493, so the dashboard said "connection refused"
and fell back to the simulator while upsd was healthy the whole time. It
binds a nonstandard port: `ss -ltnH` + a NUT handshake found it, and
`upsc -L localhost:3051` lists both batteries. No host config had to
change — dev now forwards 3494 -> 3051 and `/ups` shows real numbers,
including an honest "battery is 5.3 years old" on the APC.

Docs now say what to check before blaming the service (`ss -ltnH`,
`printf 'LIST UPS\n' | nc 127.0.0.1 PORT`, `upsc -L host:port`), and the
remaining UPS gap is rewritten: reads work, instant commands still need a
scoped upsd.users entry — which needs a *read* of that file, because
`tee` writing it blind would drop the users upsmon authenticates as.

Real-hardware quirks recorded while verifying: battery.mfr.date is the
date that means something (battery.date is often an unset placeholder),
CyberPower reports `battery.mfr.date: CPS`, and neither driver reports a
battery temperature — all three already render as unknown rather than a
invented number.

LLM-Generated: true
2026-10-16 19:00:44 -04:00

234 lines
16 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# AGENTS.md — homelab dashboards
The plan, the rules, and the environment facts an agent needs to work on this repo without
re-deriving them. `README.md` is the operator-facing how-to; this file is the why, the
invariants, and the state of the fleet.
## What this is
Three dashboards for one homelab, behind one domain, in one process, backed by one SQLite
file — plus an overview page that says which of the three you need:
| Route | Question it answers | Source |
| --------- | ------------------------------------------------------------------------------ | ------------------------------------------------- |
| `/` | Is anything wrong, and where do I look first? | all three, in one request |
| `/system` | What are my machines doing — CPU, memory, disk, GPU, network, and the history | `agent/host_agent.py`, our own stdlib agent/host |
| `/llm` | Tokens/sec, active sessions, queue depth, KV pressure, latency percentiles | gufo (llama.cpp family) + vLLM `/metrics` |
| `/ups` | Battery health, runtime left, power events, battery-test buttons | NUT `upsd` on 3493 (our own wire-protocol client) |
History is a first-class feature, not a sparkline afterthought: every number worth graphing
is stored, rolled up (raw → 1m → 1h), and served from `/api/*/history`.
## Non-negotiable rules
These are the things that make the numbers trustworthy. Breaking one is a bug even if the
page still renders.
1. **Read-only by construction, with exactly one exception.** Nothing in this app writes to
an upstream except `POST /api/ups/command`. That endpoint is gated four times
(`NUT_ALLOW_ACTIONS`, not `DASH_READ_ONLY`, the upsd.users account actually having the
command, and a UI confirmation — `DANGER` for anything that can cut power) and the server
re-checks every gate on every request. Hiding a button is not a safety control.
Commands that would cut output are refused outright while the UPS is already on battery.
2. **Never invent a number.** A value the upstream does not publish renders as `n/a`, never
as `0`. Every derived value carries the `source` string it came from and `derived: true`
so the UI can print *how* it was obtained (`computed:Δtokens/Δt`, `Δ10.0s`). Aggregating
two different series into one rate is the failure mode this rule exists to catch — the
rate estimator is keyed by the *resolved* upstream series name for exactly that reason.
3. **Unconfigured is not broken.** A source with no env config answers
`404 {"configured": false}` **without dialling**, and the page says "not configured".
A red panel for a server the operator never installed destroys the signal from the
panels that matter.
4. **One dead source must not blink another.** Each source is its own asyncio task with its
own timeout and health record (`poller.py`). A failed poll keeps the last good payload and
marks it stale in the UI instead of zeroing it. Transitions write events; repeated failure
writes one line, not 500.
5. **No CDN, no build step, no internet at runtime.** Every asset is served by this app;
charts are hand-rolled SVG (`web/static/charts.js`). The engines live on a network with
no outbound access — a CDN reference is a request that never comes back.
6. **Never leak a credential.** Target URLs may carry a userinfo token; `/api/config`
exposes them only through `Target.display_url`, which strips userinfo. No token,
password, or personal hostname goes into tracked files, fixtures, or the browser.
7. **Verify against the deployed upstream; never guess a metric name.** Field maps in
`sources/llm.py` and `sources/nut.py` were captured from the running engines and NUT
2.8.5, and are pinned by fixtures in `tests/fixtures/`. Re-capture with
`scripts/capture-fixtures.sh` (and `scripts/capture-node-exporter.sh` when comparing
exporters) rather than trusting a README or a memory of an upstream.
8. **Keep dependencies current on purpose.** LLM-written version floors are usually stale.
Check after touching dependencies: `uv pip list --outdated` must come back empty.
Python is 3.14 (`requires-python >=3.14`, ruff `py314`, pyright `3.14`, Containerfile
`python3.14`) — do not lower these to make something else work.
9. **SQLite owns the history and must stay bounded.** Writes go through `store.py`; new
metrics need a rollup path and a retention story, or a year of charts becomes a disk
emergency. Put the DB on a volume in deployment.
10. **The dev server stays up while work happens** (`./scripts/dev-server.sh restart`,
http://127.0.0.1:8090), and UI changes are verified in a real browser with a screenshot
before they are called done. `data/logs/*.png` is where those land.
## Architecture
```
agent/host_agent.py (each host) gufo / vLLM upsd (NUT)
│ GET /snapshot │ GET /metrics │ LIST UPS / LIST VAR / LIST CMD
▼ ▼ ▼
collectors.py ── fetch, one UpstreamError type, no writes except run_ups_command ──┐
│ parse + Δcounter/Δt │
▼ ▼
sources/host.py · sources/llm.py · sources/nut.py poller.py (task per source)
│ Result(payload, samples, events) │
▼ ▼
store.py ── SQLite (WAL): sample(source, host, metric, res, ts) + event ──► api.py ──► web/
```
Responsibilities, one line each:
- `agent/host_agent.py` — stdlib-only (3.10+), reads `/proc`, `/sys/block`, `/sys/class/drm`,
`statvfs`; serves `GET /snapshot` + `GET /info` + `GET /health`. Refuses to bind
off-loopback without a token (exit 2). Counters stay counters: the dashboard computes
rates so the agent never remembers who polled it last.
- `config.py` — env only, no config file format, no CLI flags. `.env` is a *seed*; a real
env var always wins. Defaults are safe except the sources, which default to unset.
- `poller.py` — job loop, health records, stale/last-good semantics, transition events.
- `collectors.py` — the fetch half. `NutMonitor` owns per-UPS transition bookkeeping.
- `sources/host.py` — snapshot → payload + samples; reboot detection; GPU series per card
(`gpu.busy_pct@<index>`).
- `sources/llm.py` — gufo + vLLM field maps (`GUFO_SERIES`, `VLLM_SERIES`,
`VLLM_HISTOGRAMS`), measured Δ rates, prefill speed as
`mean(prompt tokens)/mean(prefill time)`, session list from gufo `/slots`.
- `sources/nut.py` — upsd client, `UpsReading`, `VAR_MAP`, `assess()` (explicit checks, not
a mystery score), `COMMANDS` catalog with risk tiers, `available_commands()` filtering,
kelvin-vs-celsius normalisation.
- `sources/nut_sim.py` — a **labelled** simulator so the UPS page is developable without a
battery. It must never be the default, and every payload it produces says `simulated`.
- `prom.py` — Prometheus text-exposition parser (in-house; only for engines we don't own).
- `rates.py` — Δ/window estimator, keyed by resolved series name.
- `store.py` — `sample(source,host,metric,res,ts)` + `event` + `meta`, rollups, pruning.
- `api.py` — GETs everywhere plus the one POST. `/api/config` is redaction boundary.
- `app.py` — assembly; `create_app()` takes injectable settings/store so tests build an app
with an in-memory DB and no targets.
- `web/` — four static pages, one stylesheet, `charts.js`. No framework.
Metric naming: dotted (`cpu.usage_pct`, `mem.used_pct`, `disk.used_pct@/srv`,
`gpu.busy_pct@0`, `llm.decode_tps`, `ups.charge_pct`), `@stream` for per-device series.
That scheme is the history API's key — treat it as a public interface.
## The fleet (real environment, verified 2026-10)
| Host | ssh alias | What it gives |
| ----------------- | ------------------ | -------------------------------------------------------------------- |
| `driveripper` | `driveripper-ops` | Threadripper 24c/48t + Radeon AI PRO R9700, vLLM `:8000`, **upsd**, the dashboards |
| `deskwork` | `deskwork-ops` | Strix Halo (Radeon 8060S iGPU), gufo `:8731` |
| `gateway` | `gateway-ops` | router, no GPU |
- Agents run from `~/lab-agent/host_agent.py` on each host, forwarded to `127.0.0.1:9121/9122/9123`
by `scripts/dev-tunnels.sh` (`DEV_TUNNELS`). Nothing listens on the hosts in dev.
- Engines are reached directly: gufo `deskwork.reeselink.com:8731`, vLLM `driveripper.reeselink.com:8000`.
- NUT 2.8.5 on driveripper: **configs live in `/etc/ups/`, not `/etc/nut/`**, and **upsd is
on port 3051, not 3493**. Nothing listens on 3493 at all, so a default client reports
*Connection refused* and it looks like a dead service — `ss -ltnH` plus `printf 'LIST UPS\n'
| nc 127.0.0.1 3051` (answers `BEGIN LIST UPS`) is how that was pinned down. Two UPSes are
exported over USB and read live through `DEV_FORWARDS="3494:driveripper-ops:3051"`:
`apc` = APC Back-UPS RS 1500MS, `cyberpower` = CyberPower PR1500LCDRT2U.
Real-hardware quirks the parsers already handle: `battery.mfr.date` is the useful date
(`battery.date` is often an unset placeholder like `2001-09-25`), CyberPower reports
`battery.mfr.date: CPS` (not a date → `unknown`, never a fake age), neither driver reports
a battery temperature, and `ups.test.result: No test initiated` is the factory state.
- Host access is via ssh keys as `ops`. Passwordless sudo exists but is command-scoped; the
set we rely on is documented in `deploy/nut-sudoers` (additions are listed there for the
work that is still blocked).
## Commands
```bash
uv sync --python 3.14 # deps + editable install
cp .env.example .env # production-shaped config
cp .env.dev.example .env.dev # dev-only: ssh tunnels + live targets
./scripts/dev-tunnels.sh start # agents (9121-9123) + DEV_FORWARDS (upsd 3494)
./scripts/dev-server.sh restart # keep http://127.0.0.1:8090 up
./scripts/dev-server.sh status # per-source ok/DOWN
./scripts/dev-server.sh logs
uv run pytest # hermetic: 258 tests, no network
uv run pytest --cov # coverage gate (~94%)
uv run pytest -m live --live # opt-in: real fleet / engines / upsd
uv run ruff check src tests agent && uv run pyright
./scripts/capture-fixtures.sh # re-record ground truth
```
Deployment: `Containerfile` (two-stage, `uv sync --frozen`, runs as uid 10001 on `0.0.0.0:8090`,
SQLite under `/var/lib/dashboards` — put a volume there) and `deploy/install-agent.sh`
per monitored host (systemd unit, own user, `--token-file`, `ProtectSystem=strict`).
The quadlet unit + env template + nginx/SNI live in the deployment repo, like every other
service here.
## Testing policy
**Real captures for shape, fakes for behaviour, `live` for drift.**
- Anything that must match an upstream — `/proc` layouts, vLLM series names, NUT framing —
is asserted against a verbatim capture in `tests/fixtures/`. If the schema drifts, a
fixture test fails before a dashboard does.
- Anything that needs a failure mode — upsd refusing a command, an engine 500ing, a host
rebooting mid-poll, a counter reset — is a fake in `tests/conftest.py`.
- `live` (`tests/test_live_fleet.py`) re-runs the production code paths against the real
fleet, engines, and upsd. Skipped unless `--live`; each test skips when its source is
unset, so partial fleet availability is normal. **Live tests must not write** — a battery
test on hardware something is plugged into is not a test.
- The agent's real-`/proc` test (`tests/test_agent.py`) touches only the box running pytest,
so it stays in the default run and is *not* marked `live`.
- Coverage gate: 80% is the floor, ~94% is where we are; keep it there. API tests use
`create_app()` with an in-memory DB, never a real target.
## UI conventions
Hand-rolled SVG (`charts.js`), one stylesheet, dark/light toggle, `Δ<window>` labels on
measured rates, `n/a` for the unknown, `SIMULATED` badges on modelled data, per-source status
dots in the header, window chips (1h…90d) on history pages. A panel that cannot get data says
why in the panel — the operator should never have to open devtools to learn that a source is
unconfigured. Escape anything upstream-provided through `DashCharts.escapeHtml`.
## Known gaps / next work
1. **UPS instant commands are read-only in practice.** Reads work against real upsd (see
above), but every button is gated off with "NUT_USER / NUT_PASSWORD must name a user with
`actions` in upsd.users" because no such user exists yet. Creating one safely needs a
*read* of `/etc/ups/upsd.users` first — `sudo tee` can write the file but overwriting it
blind would delete the users upsmon already authenticates as, which can take the box down
at the wrong moment. `deploy/nut-sudoers` lists the read rules; once they are in, add
`[dashboards]` with `instcmds` limited to the battery tests, put the credentials in
`.env.dev`, and the buttons come alive. Never grant `actions = -`.
2. **GPU coverage is AMD only.** `host_agent.gpus()` reads amdgpu DRM sysfs
(`gpu_busy_percent`, `mem_info_vram_*`, hwmon temps, clocks). That covers the current
fleet (R9700 + Strix Halo iGPU; gateway has none). An NVIDIA host would report no GPU at
all — needs a `nvidia-smi`/NVML or DCGM path, and a fixture from a real card before the
field map is written.
3. **No remote yet.** Two commits, no `origin` — the user is providing it.
4. **UPS history depth.** Events and the numeric series are stored; long-window battery
health (capacity fade over months) has the rollups but no dedicated view.
## Locked decisions (and why)
- **SQLite, not Prometheus/Grafana.** Handful of boxes, 1–10s resolution, one file the
container owns. Rollups keep a year of charts at a few hundred MB.
- **Our own stdlib host agent, not node_exporter.** One JSON snapshot with exactly the
fields the page needs (GPU model strings, per-mount usage, temperature labels) versus
~1500 series and a re-labeling layer; no dependency to install, `ProtectSystem=strict`
friendly, and read-only by construction. `scripts/capture-node-exporter.sh` remains to
compare ground truth if that is ever revisited.
- **Our own NUT client, not `pynut`/`upsc`.** The protocol is ~10 line commands, the
third-party libs are subprocess-based or stalled, and we need instant commands with
explicit gating.
- **In-house Prometheus parser.** Only two upstreams use the format; keeps `prometheus_client`
out of the dependency set.
- **Port 8090**, inherited from the `llm_monitor` prototype this started from: 8000 is vLLM
and 8731 is gufo in this fleet.
- **`.env` is a seed, never an override** — container/systemd env must win.
## Definition of done (per change)
`uv run pytest` green · coverage not down · `ruff` + `pyright` clean · `uv pip list --outdated`
empty if deps moved · dev server restarted and `/api/health` sane · UI change screenshotted
in a browser against **live** data · fixtures re-captured if an upstream contract changed ·
this file and `README.md` updated when a rule, command, gap, or fleet fact changed.