19cfedfddf720ff94e800cf2764208eb0a210732
5
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
3d5ccd7a39 |
phase: 07_llm_monitor_style_pages
**Phase 07 final verification pass — all tasks already in `complete/`; every criterion re-verified live.**
- **Old slot table gone**: no `#slots-card`/`#slots-table`/`renderSlots` in HTML/JS/CSS (only the new grid's `.slots-empty` *class*); pinned by `test_the_broken_slot_table_is_gone_from_html_js_and_css`.
- **`tests/fixtures/slots_gufo.json`**: present; live `GET ${GUFO_BASE_URL}/slots` this pass matches it key-for-key (row + `next_token[0]`), so the capture is reproducible; drift proven to fail (mutation tests + live `test_gufo_slots_answer_the_pinned_shape`, 9 live tests pass).
- **Aggregate block**: live page shows `2 of 2 engines`, running/waiting/prompt/decode/total-tokens straight from `fleet_totals()`, dot `ok`, no verdict colour; on a throwaway single-engine instance (:8091, private temp DB) `#fleet` is `hidden`, one full-width strip card + one panel, zero banners → "one clean half".
- **Strip + slot grid on live data**: 2 `.card.stat` (KV bars `bar ok` 13 %/0 %), gufo grid rendered real cards incl. a busy slot (`#2189`, 67849 prompt tok, 99 % cache share, `processing`), vLLM note-only with no grid; no `NaN`/`undefined` anywhere. Screenshots: `data/logs/llm-phase07-final-live-{two-engines,single-engine}.png`, `ups-charts-aria-labels.png`.
- **Defect found in earlier work and fixed**: `/ups`' four `LineChart`s shipped no `ariaLabel`, violating AGENTS.md's "every chart names itself for assistive tech" (`/system`+`/llm` were pinned, `/ups` wasn't) → added labels to `page-ups.js` and `test_every_ups_chart_names_itself_for_assistive_tech`; browser-verified `role="img"` + label on all four.
- **Gate**: `bash .agents/validate.sh` → **exit 0**; `uv run pytest --cov --cov-fail-under=94` → **604 passed, 9 skipped, coverage 97.91 %**; `uv run ruff check src tests agent` → All checks passed; `uv run pyright` → **0 errors**; `node --check` every page script ok; `uv run pytest -m live --live` → **9 passed**; `uv pip list --outdated` empty.
- **Docs**: README + AGENTS.md reviewed end-to-end; fixed test count (582→604), `/llm` source column + both architecture diagrams now name gufo `/slots`, AGENTS.md agent line gained `GET /schema` + status page, ariaLabel convention now covers all three chart pages, README Testing block now lists `bash .agents/validate.sh`. Env-var table, agent/install flags, Containerfile facts, `/api/*` shapes, range chips, remote URL all verified accurate — no other changes needed.
- **Live-infra**: no fleet/host/config change; the temp :8091 instance, its temp DB and the fake processes are removed; dev server restarted and `/api/health` `ok` (all 6 sources ok). One thing I deliberately did **not** touch: the gitignored local `.env.dev` still carries a comment claiming the NUT `[dashboards]` account has only battery-test `instcmds`, whereas AGENTS.md/README record `instcmds = all` (verified on hardware 2026-10-17) — operator-owned file, flag for the operator to reword.
- **Next pending phase**: `08_events_paging_and_copy`.
|
||
|
|
de325caa49 |
phase: 06_system_page_gpu_verdicts
All criteria verified and the project is fully green.
**Verified (final pass — all 3 phase-06 tasks were already in `complete/`)**
- `classify("gpu.busy_pct", 99)` / `gpu.mem_used_pct` → `None`; `THRESHOLDS` has no `gpu.*` row; `alerts.py`/`api.py` carry no GPU verdict; live browser: deskwork GPU at **91 %** and **98 %** renders `class="hero"`, `color=rgb(22,25,31)` (plain text), no bar, no `.sev-*`.
- GPU temp on the hero `.sub` from live agents: `Radeon 8060S Graphics · VRAM 165.1 MiB / 512.0 MiB · pool 78% · 48 °C`, R9700 `· 40 °C`, gateway prints none (no `n/a`, no `0 °C`).
- Charts collapsed by default: fresh load = 3 panels / 3 toggles / **0 open / 0 `<svg>`**; expand → 3 SVGs (510 px wide), repaints across polls (legend 3.3 %→5.6 %), collapsed siblings keep their own height (803 vs 358/339).
- `gpu.busy_pct@0` still answers from `/api/system/history` (345 points) — verdict gone, data intact.
**Tests / lint / coverage**
- `bash .agents/validate.sh` → **EXIT=0**; `uv run pytest --cov --cov-fail-under=94` → **550 passed, 8 skipped, 97.91 %**; `uv run ruff check src tests agent` → clean; `uv run pyright` → 0 errors; `node --check` all scripts clean; `uv pip list --outdated` empty.
- `uv run pytest -m live --live` → **8 passed** (real agents/engines/upsd); dev server restarted, `/api/health` all sources `ok`.
- New screenshots: `data/logs/phase06-final-collapsed-default.png`, `data/logs/phase06-final-expanded-gpu-busy-uncoloured.png`.
**Completion criteria:** classify→None ✅ · pytest+94 % gate ✅ · ruff+pyright ✅ · validate.sh ✅ · screenshots of the three behaviours on live data ✅ · AGENTS.md severity section claims no GPU rows ✅
**Docs:** fixed 3 items — (1) `AGENTS.md` pytest count stale (546 → 550); (2) `app.js` `severityFor` docstring still claimed "`page-ups.js` still calls it (phase 05 converts it)", contradicting the code/tests/AGENTS.md (comment-only); rest of README/AGENTS reviewed in full (env table vs `config.py`+`.env.example`, agent routes incl. `/schema`, alerts rules, page descriptions, contracts) — consistent.
**Notable:** fixed a real pre-existing defect in `scripts/dev-server.sh` — `stop` slept 1 s and deleted the pidfile without waiting for exit, so `restart` with a browser open overlapped two servers on one SQLite file, producing a `database is locked` store refusal that `/system` rendered as a red event. Now waits (bounded 20 s) then SIGKILLs; verified a restart with live polling logs no such error/event. No live infra config was changed.
**Next pending phase:** `.agents/phases/todo/07_llm_monitor_style_pages`
|
||
|
|
34854d32af |
phase: 05_ups_hero_battery_glyph
**Phase 05 final pass — all criteria met; whole project 100 % green.**
Verified (live upsd + isolated simulator):
- Real `apc`/`cyberpower`: Charge/Load/Runtime are the card's three largest elements (38.4 px vs 15.2 px next), coloured only by API `severity` — live right now 100 % ok / 79.0 % **warn** / 5m **fail**; glyph fill = charge (100/100 viewBox units, `--ok` token), `<title>` "apc: Charge 100 percent, on line"; SIMULATED hidden; battery °C `n/a` uncoloured; every button disabled with its reason; `confirm_text: DANGER` on power-cutting commands; **0 non-GET requests** → `data/logs/ups-verify-live-{card,full}.png`.
- Simulator on `:8091` (own `/tmp` DB, killed after): caution dialog → Cancel, dangerous dialog → Run disabled until `DANGER` → Cancel, **0 POSTs**; one deliberate quick test *to the sim only* flipped the card to `OB` (glyph `stroke-dasharray="7 5"`, "on battery", health "discharging, on battery") then `OL CHRG` (bolt) then `OL` → `ups-verify-sim-{dialog-caution,dialog-danger,onbattery-button,onbattery-page,charging-button}.png`; glyph matrix `ups-glyph-*.png` (100/mid/low/unknown/empty/unrated, dark/light/200 %) present; `grep -c "function battery"` = 1.
Defects found in earlier work and fixed:
1. **`poller.py` could stop polling in silence** — 4 of 6 dev-server sources had frozen `attempts` (ages 12–38 min) while `/api/health` still said `ok: true`: the store-write half of `run_once` was outside the `try`, and a dead task's exception is never retrieved. Now `_commit()` moves `last_ok` only after the write lands, `_store_refused()` reports it (`ok:false`, real reason, one `store-error` event + one `recording` on recovery, payload kept), and `_loop()` catches anything that escapes and keeps polling — 4 new tests in `tests/test_poller.py`.
2. **`nut_sim.py` (modified by this phase) sat at 83 % coverage**; its whole command path was untested. Added tests (every advertised command implemented, unknown → `ValueError`, alarms → card + `assess()` fail, `NUT_SIMULATE` truthy rule) and fixed two model lies: `beeper.*` answered OK while changing nothing (now publishes `ups.beeper.status` enabled/muted/disabled) and a finished self-test never wrote `ups.test.result` (aborted writes none). → 100 %.
3. `nut_sim.from_env()` was dead code duplicating `app._truthy`; `app.py` now builds the simulator through it, so the enable gate lives once.
Tests / lint (exact): `bash .agents/validate.sh` → **EXIT=0** — `uv run pytest --cov --cov-fail-under=94` **543 passed, 8 skipped, coverage 97.91 %**; `uv run ruff check src tests agent` clean; `uv run pyright` 0 errors; `node --check` clean; repo hygiene clean. `uv run pytest -m live --live` **with `.env.dev` sourced → 8 passed** (one earlier run: 2 transient `9121/snapshot timed out` against the 4 s `HOST_TIMEOUT`; three later runs 8/8). `uv pip list --outdated` empty. Dev server restarted on the final code: `health ok`, 6/6 sources fresh.
Docs: AGENTS.md — invariant 4 extended ("nothing may stop polling in silence" + store-refusal semantics), `poller.py`/`nut_sim.py` responsibility lines, 533→543 and 96.9 %→97.9 %, "~97 %"→"~98 %". README.md — poller bullet gained the same guarantee, Testing gained "source `.env.dev` before `-m live --live`" (bare runs skip 7 of 8 live tests, which reads like a pass), Battery-test section gained the `deploy/nut-sudoers` install line and the read-before-write warning.
Notes/deviations: no live instant command was ever sent to real hardware (the four gates leave them disabled — AGENTS gap 1 unchanged); the on-battery proof was driven through the real button against `NUT_SIMULATE=1`, which is stronger than the NOTES hand-driven states. `NOTES-verify.md` under `todo/` left untouched per instructions. Next phase: **none** — 05 is the last in the PLAN.md roadmap.
|
||
|
|
b389bb4a94 |
Wire the live-test gate and pin the toolchain to 3.14
README advertised `uv run pytest -m live --live`, but there was no --live option and no `live` marker registered — the command errored out, so the one workflow that catches an upstream renaming a series did not exist. - conftest adds --live and skips `live`-marked tests without it, so the default run stays hermetic (258 passed, 6 skipped, no network). - tests/test_live_fleet.py drives the real code paths (collectors.*, NutMonitor.collect) against the fleet, both engines, and upsd. Each skips when its source is unset, and none of them may write — a battery test on live hardware is not a unit test. The host test polls twice because a rate has no second point on the first scrape. - The agent's real-/proc test stays in the default run and is explicitly not `live`: it touches only the box running pytest. - dev-tunnels.sh grows DEV_FORWARDS for services already listening remotely, which is how upsd gets reachable without opening 3493; pidfiles are now host+port so one host can carry two tunnels. - requires-python, ruff and pyright were still on 3.13 while the venv and Containerfile are 3.14, so the lock resolved for a stack nobody deploys. LLM-Generated: true |
||
|
|
c4bb374ccc |
Add homelab dashboards: system, LLM, and UPS on one domain
Three dashboards served by one FastAPI app with a SQLite history store
(raw / 1m / 1h) and hand-written SVG charts: no Prometheus, no Grafana,
no CDN, no build step. Nothing is fetched from the internet at runtime.
* system: a stdlib-only agent (agent/host_agent.py) reports /proc and
/sys counters; the dashboard turns them into rates over a labelled
window, so every number says how it was measured.
* llm: gufo/llama.cpp and vLLM /metrics are parsed by an in-house
exposition parser. Measured delta/elapsed throughput beats a native
per-request gauge, and each value carries its provenance.
* ups: a NUT wire-protocol client plus health checks that name what
they looked at. Commands are gated by NUT_ALLOW_ACTIONS,
DASH_READ_ONLY and a DANGER confirmation, re-checked server-side.
Missing values render as n/a rather than 0, and an unconfigured source
answers 404 {"configured": false} without dialling anything, so "not
deployed here" never looks like an outage.
253 tests at 94% coverage against captured real fixtures; ruff and
pyright clean.