# REFERENCE capture, not a field capture. Every LABEL here is the verbatim format string
# of the deployed smartmontools 7.5 binary (verified against its own strings and drive
# database on 2026-10-18); the values are synthetic, because no host reachable at
# reference-writing time could open a block device (fleet agents need the `disk` group —
# see README). Replace these files with hardware truth:
#   SMART_HOSTS="deskwork-ops driveripper-ops" ./scripts/capture-fixtures.sh
# which records smartctl_<host>_<dev>.txt per physical disk with serials scrubbed.
# The parse tests treat this file as the NVMe shape: Temperature/Percentage Used/
# Power On Hours/Media and Data Integrity Errors come from the health log, and the ATA
# sector attributes stay absent — n/a on the page, never 0.
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-7.2.11-100.fc43.x86_64] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       EXAMPLE NVMe SSD 2TB
Serial Number:                      SCRUBBEDSERIAL1
Firmware Version:                   FITMVT04
IEEE OUI Identifier:                0x000000
Total NVM Capacity:                 2,000,398,934,016 (2.00 TB)
Unallocated NVM Capacity:           0
Controller ID:                      0
NVMe Version:                       1.4
Number of Namespaces:               1
Namespace 1 Size:                   2,000,398,934,016 (2.00 TB)
Namespace 1 Capacity:               2,000,398,934,016 (2.00 TB)
Namespace 1 Utilization:            1,000,000,000,000 (1.00 TB)
Namespace 1 Formatted LBA Size:     512
Local Time is:      (time of capture removed by scripts/capture-fixtures.sh)

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning:                   0x00
Temperature:                        38 Celsius
Available Spare:                    100%
Available Spare Threshold:          10%
Percentage Used:                    1%
Data Units Read:                    120,000,000 [61.4 TB]
Data Units Written:                 90,000,000 [46.0 TB]
Host Read Commands:                 1,000,000,000
Host Write Commands:                800,000,000
Controller Busy Time:               100
Power Cycles:                       57
Power On Hours:                     8,760
Unsafe Shutdowns:                   12
Media and Data Integrity Errors:    0
Error Information Log Entries:      0
Warning Comp. Temperature Time:     0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               42 Celsius
Temperature Sensor 2:               45 Celsius

Error Information (NVMe Log 0x01, 16 of 64 entries)
No Errors Logged